MELAG MELAdem 47 RO System

Greater quantities of water at low cost

Read more Enquire now
Greater quantities of water at low cost

Increasing hygiene requirements in the processing of medical products can involve the frequent sterilising of instruments. The consequent increased need for high quality demineralised water is provided amply by the MELAdem 47 and at low cost. The reversal of the physical principle of osmosis is an extremely environmentally-friendly type of water processing. MELAdem 47 produces around 3-5 litres of feed water per hour, so that several MELAG steam sterilisers can be supplied at the same time.

  • Water filter system
  • Always fresh aqua dem which protects your instruments and your autoclave
  • Automatic monitoring of the water quality when connected to a MELAG Vacuklav® or Euroklav® 
  • Creates 3 litres of water per hour
  • 5 litre storage tank
  • Counter fitted tap
Videos

Recommissioning your decon room post COVID-19

)

The following maintenance tasks should be carried out at the stated intervals in order to ensure trouble-free operation.

Frequency

Maintenance Task

Daily

Check the permeate using the control monitor water quality (if installed)

Every 12 months

Replace the fine filter (pre-filter)

Every 12 months

Replace the activated carbon filter

Every 12 months

Check the pipes and screw connections for leaks, compressions or kinks

Every 12 months

Check the pre-pressure of the empty storage container at the underside of the container

As necessary

Change of battery, periodically

As necessary (if conductivity values are poor)

Renew the ion-exchange resin cartridge

If the quality of the water is bad because of the local conditions, carry out half-yearly maintenance of the water treatment unit.

Various measures are necessary before or after periods of inoperation.

Period of inoperation

Precautionary measures

Up to 2 weeks

Turn off water intake

Up to 4 weeks

Turn off water intake, empty storage container

On resuming operation after more than 4 weeks

Swill out equipment and storage container and install new fine filter (pre-filter), activated carbon filter and ion exchange resin

As of 2 months

Disinfection of the unit, please call our equipment servicing team on 0800 028 4749.

Replacement of the Fine filter (pre-filter)Image

  • A new fine filter cartridge should be inserted every 12 months, or more often if high levels of impurity have led to loss of pressure.
  • Turn off the mains water supply and the stop tap of the storage container.
  • Allow some water to flow out of the supply tap to equalise the pressure in the system.
  • Unscrew the filter housing (a) with the filter wrench from the head (b). Lead the wrench from bottom to top through the filter housing and screw the filter wrench to the left.

The filter housing is full to the brim with water. Pour off the water.

  • Remove the filter cartridge (1) and wash out the housing with normal water.
  • Take the sealing ring out of the housing (a), clean, give a slight coating of silicone and replace.
  • Place the new filter cartridge in the housing.
  • Screw down the housing slightly by using the filter wrench.
  • Turn on the mains water supply and open the stop tap on the storage container.
  • Check that all parts sit tightly, with no leaks.

Replacement of the activated carbon filterImage

A new activated carbon filter should also be inserted every 12 months, or more often if necessary.

  • Turn off the mains water supply and the stop tap of the storage container.
  • Allow some water to flow out of the supply tap to equalise the pressure in the system.
  • Unscrew the filter housing (a) with the filter wrench from the head (b). Lead the wrench from bottom to top through the housing and screw the filter wrench to the left.

The housing is full to the brim with water. Pour off the water.

  • Remove the activated carbon filter (1) and wash out the housing with normal water.
  • Take the sealing ring out of the housing (a), clean, give a slight coating of silicone and replace.
  • Place the new activated carbon filter in the housing (with the arrow pointing upwards!).
  • Screw down the housing slightly by using the filter wrench.
  • Turn on the mains water supply and open the stop tap on the storage container.
  • Check that all parts sit tightly, with no leaks.

It is important to exchange the filter catridges regularly in order to avoid damage to the reverse-osmosis module which would shorten its operational life.

Replacement of the ion exchange resin

Image

When the mixed-bed resin is exhausted (inadequate water quality of the permeate) then it must be exchanged:

  • Turn off the mains water supply and if necessary empty the storage container.
  • Unscrew the filter housing (a) with the filter wrench from the head (b). Lead the wrench from bottom to top through the housing and screw the filter wrench to the left.

The housing is full to the brim with water. Pour off the water.

  • Take out the mixed-bed resin (1) and replace it by a new mixed-bed resin.
  • When placing it, please observe that the flat packing on the mixed-bed resin (1) is upwards (arrow pointing upwards).
  • Take the sealing ring out of the housing (a), clean, grease slightly and replace.
  • Re-insert the mixed-bed resin into the housing (a).
  • Tighten the housing slightly by using the filter wrench.
  • Turn on the water supply and open the stop-tap of the storage container.
  • Check that all parts sit tightly, with no leaks.

Future-Proof your practice today with our cover options

We know an unexpected breakdown in your practice can be a massive headache for you and your patients - which is why we have a dedicated team of 50 people ready to provide you with a range of comprehensive cover options for your practice equipment, giving you complete peace of mind and minimising the cost of an unexpected breakdownYou can depend on us.

High tech digital support specialists

With Protection Cover, you get free access to our team of 10 high tech digital support specialists who can help with digital imaging, lasers and CAD/CAM. For the simpler problems, we also have technicians, who are dedicated to helping you over the phone. You can also at a small cost, use their services even if you don't have cover.

Protection cover

Invest in your practice - choose our comprehensive protection cover. For 12 months we will cover the items you want. It includes an annual service, emergency breakdown, labour and access to our high tech digital support specialists.

Annual service

To get optimum performance from your equipment and to conform to manufacturer’s recommendations, an annual service could be just what you’re looking for. It’s carried out by our accredited team and includes a 3 month warranty on the work.

Emergency breakdown service

We are never far away in an emergency. Unplanned breakdowns are a headache for any surgery. We are more than happy to help.

Call us today on 01 4565288.

Enquire Now

Our equipment team will use the information you provide to respond to your query as promptly as possible.

You could ask about a FREE one-to-one consultation with one of our specialist team, quotation, demonstration of the latest equipment, or any other question you may have in helping you make an informed decision.

Contact Permission (not required)

We’d love to send you exclusive offers and latest news stories from Henry Schein Dental by e-mail. We’ll always treat your personal details with care and will never sell them to other companies for marketing purposes.